PulseGuard
Pulsation dampeners that do, fluid flow goes through.
Fluid Flow Control Animations
Fluid Flow Control Animations
PulseGuard Inc. Pulsation Dampers

Pulsation Dampeners for Screw Pumps

Pulsation Dampeners for Vane Pumps

Pulsation Dampener for Screw Pump

Screw pump piping system pulsation dampening. Curing the kick in screw pump pipe systems with the PumpGuard pulse dampener.

Pulsation Dampeners - Flow and PressurePulsation Dampeners - Flow and PressurePulsation Dampeners - Flow and Pressure

Because flow is so slow, there is time to flow up, come to a stop, and flow back down a “T” – on the other hand, whatever the residual pressure pulsation level is, it will still shake the pipes.

Volume accumulator only is bigger, better, or “bonkers”?
The tide ebbs & flows slowly. But the impact from the velocity of waves does the damage fast.
Mass of liquid in a pipe is transferred at not above 180 inches/sec or say 460 cm/sec. Pressure in a fluid travels at mach 1 (in air), in harder substances (liquid) is transferred at up to 4000 MPH, or say 140,000 cm/sec.

CONCLUSION:- Damping "non Newtonian liquids" requires designs that do not pack cake and trap material against the vessel wall. Constant agitation 1st in 1st out is a clear advantage. No flow reversal in a single opening enables max smoothness. Only flow through dampeners suit screw & worm systems.

A pulsation dampener intercepts pressure pulsation and smoothes flow fluctuations, is smaller and costs less to install.

Pulsation Dampeners InfoPulsation Dampeners Info

ISO 9001 registered by DNV QA in 1995.
Dampeners produced in NC USA, are to our design code (in excess of ASME VIII which states non- applicability to dampeners) or they may be “U” stamped at extra costs but have all warranty removed.



Pulsation Dampener Selection for Screw Pumps

Removing the "kick" from screw and "worm" pump piping systems.

Pulsation Dampeners for Screw Pumps

Your pump connections suit its flow, and its fluctuations are related to the pump type, so the dampeners have been pre-selected for you. Simply choose the dampener that matches your connection size. Or call us, with your RPM, flow rate, and required smoothness, so that we can make a specific selection for you.

Pulsation Dampeners for Screw Pumps

Pulsation Dampener for Screw Pump

Pulsation Dampener for Screw Pump

Flex Tube Pulsation Dampeners

Pulsation Dampeners - HP Discharge

Pulsation Dampeners Information

 

Impelling Pumps
Screw
Reciprocating Pumps
Air Operated Double Diaphragm | Dosing | Injection | Metering | Plunger / Piston | Power
Rotary Pumps
Centrifugal | Gear | Lobe | Vane
Other Pump Types
Hose / Peristaltic | Progressive Cavity

Pulsation dampeners are designed to address pressure pulsation, which is caused by the resistance of the system to flow. Therefore our pulsation dampeners focus on the system related responsibility and are less related to pump liability. PUMPS make FLOW, SYSTEMS cause PRESSURE, pressure pulsation is a system response, AND a system responsibility NOT a pump manufacturers liability. When you see a pulsation dampener or a pump of particular interest, please request literature dedicated to that subject.
"Dampeners that do, flow goes through, but pressure pulsation does not."

 



Fluid Flow Control Fluid-Flow-Control.com The Fluid Flow Control Source Pumps Accumulators Filters Dampers Heat Exchangers Valves Mixers P.I. / Pressure Indicators Controls Meters Vessels