PulseGuard
Pulsation dampeners that do, fluid flow goes through.
Fluid Flow Control animations by Liquid Dynamics.
PulseGuard Inc. Pulsation Dampers

Pulsation Dampeners for Gear Pumps

Pulsation Dampeners for Vane Pumps

Pulsation Dampeners for Gear Pumps

Removing the ripple from gear pump piping
How to ensure lowest in place cost and most performance by standard installation methods. Even these, THE SMOOTHEST of all POSITIVE DISPLACEMENT PUMPS have pressure disturbances, which are normally not important, but when they are connected to piping systems that were not designed, will cause pulsation.
1. How it starts
2. A partial fix
3. True solution - with elastomers
4. With PTFE or "FlexFlon"
5. No particulate
6. With dirt
7. Big but best

Gear Pump
The final full meshing of the gear tooth tries to compress some almost totally trapped liquid, to a very high pressure. The decompression escapes back through the gear tolerance gap and makes a pressure spike.

Pulsation Dampener on a Gear Pump
High frequency pressure pulsation is dissipated by wide ratio of hole size through which it enters to diameter of chamber. Above is a partial fix when stainless and an elastomer are compatible.

Pulsation Dampener for Gear Pump
A better solution, larger diameter than #2. When metal & elastomer are compatible.

Pulsation Dampeners for Gear Pumps
FlexOrber high and low pressure from hydroformed dishings, with "FlexFlon" or E.I. DuPont Teflon have the largest chamber diameter to port hole ratio - combine best HF pulse interception with flow velocity smoothing.

Pulsation dampeners with no moving parts, and no foam to degrade or clog.

"Maintenance free dampeners" An admission that pulsation is acoustic not volumetric.

Pulsation Dampeners with No Moving PartsAcoustic Pulsation DampenersPulsation Dampeners or Snubbers
Application: Where miniscule fluctuations in flow velocity are of little concern, and you simply need to prevent pressure pulsation and resonance, then WaveGuard is the answer. The WaveGuard/HO uses the Helmholtz Orifice technology for greater efficiency for size. The answer to high pressure, medium high frequency, low volumetric pulsation, and for systems without suspended solids. By exploding pressure peaks through small holes into large chambers pulsation is destroyed. WaveGuard/MT is for particulate laden systems and is larger. WaveGuard/Cer is for the ultimate acoustic performance. It has ceramic balls and breaks pressure waves.



Pulsation Dampener Selection for Gear Pumps

Pulsation Dampeners for Gear Pumps

Gear Pump Pulsation Dampeners

Pulsation Dampener - PipeGuard

Pulsation Dampener - PipeGuard

Bladder Pulsation Dampener for Gear Pump

Pulsation Dampener - Low Pressure

Pulsation Dampener - High Pressure

PTFE Diaphragm Pulsation Dampeners for Gear Pumps

High Pressure Pulsation Dampener for Hazards

Pulsation Dampener - PTFE Diaphragm

Acoustic Pulsation Dampeners for Gear Pumps

Pulsation Dampener With No Moving Parts

Pulsation Dampener or Snubber

Pulsation Dampener with Orifice

Pulsation Dampeners Information

Pulsation Dampeners for Flow FLuctuation

 

Impelling Pumps
Screw
Reciprocating Pumps
Air Operated Double Diaphragm | Dosing | Injection | Metering | Plunger / Piston | Power
Rotary Pumps
Centrifugal | Gear | Lobe | Vane
Other Pump Types
Hose / Peristaltic | Progressive Cavity

Pulsation dampeners are designed to address pressure pulsation, which is caused by the resistance of the system to flow. Therefore our pulsation dampeners focus on the system related responsibility and are less related to pump liability. PUMPS make FLOW, SYSTEMS cause PRESSURE, pressure pulsation is a system response, AND a system responsibility NOT a pump manufacturers liability. When you see a pulsation dampener or a pump of particular interest, please request literature dedicated to that subject.
"Dampeners that do, flow goes through, but pressure pulsation does not."

 



Fluid Flow Control Fluid-Flow-Control.com The Fluid Flow Control Source Pumps Accumulators Filters Dampers Heat Exchangers Valves Mixers P.I. / Pressure Indicators Controls Meters Vessels